FGL-50/11/1
1
50
1000mm
420mm
1000℃
3
K
Availability: | |
---|---|
Quantity: | |
Applications
The tube furnace design is available in both open and non-open options, with diverse combinations to meet the requirements of a wide range of laboratory experiments, with high purity quartz tubes as the furnace chamber for high cleanliness. Different vacuums can be obtained, and a variety of process gas control can also be realized. The equipment is exquisite and beautiful in appearance, with good peripheral expandability, suitable for universities and research institutes for experiments.
Features
1. Application temperature of RT-1000℃;
2. Intelligent programmable temperature controller with precise control, which can edit, store and call multi-segment program;
3. furnace shell structure, double-layer shell air-cooled structure;
4. stainless steel double sealing flange seal;
5. adjustable flange support structure at both ends to extend the service life of the quartz tube;
6. LED high-strength, vandal-resistant, all stainless steel buttons, durable;
7. over-temperature protection function, when the temperature exceeds the allowable set value automatically power off;
8. safety protection when the furnace body leakage automatic power off;
9. K-type thermocouple, accurate temperature control
10. Heating element is ceramic fiber heating module, heating wire embedded structure
Additional Options
Vacuum system: (rotary vane mechanical pump, diffusion pump unit, molecular pump unit);
Atmosphere system: (float flow meter, mass flow meter);
Note: options need to be configured to expand the cabinet
Technical Parameters
Equipment Model (Serial No.) | Operating Temperature (℃) | Outer Diameter of Furnace Tube (φ mm) | Length of Furnace Tube (L mm) | Heating Length (mm) | Number of Temperature Zones (zones) | External Dimension mm (W×H×D) | Voltage (V) | Power (kW) |
FGL-25/11/1 | RT~1000 | 25 | 1000 | 320 | 1 | Desktop Touch Screen 635*560*380 | 220 | 1.2 |
FGL-50/11/1 | RT~1000 | 50 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | 3.0 |
FGL-60/11/1 | RT~1000 | 60 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/1 | RT~1000 | 80 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-50/11/2 | RT~1000 | 50 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | 3.2 |
FGL-60/11/2 | RT~1000 | 60 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/2 | RT~1000 | 80 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-50/11/3 | RT~1000 | 50 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 | 6.0 |
FGL-60/11/3 | RT~1000 | 60 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/3 | RT~1000 | 80 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 |
Notes:
1. Other pipe diameters, the number of temperature zones and the length of the heating zone can be customized according to customer process requirements.
2. Excluding flange, furnace tube, flange bracket and other vacuum unit connection dimensions.
Applications
The tube furnace design is available in both open and non-open options, with diverse combinations to meet the requirements of a wide range of laboratory experiments, with high purity quartz tubes as the furnace chamber for high cleanliness. Different vacuums can be obtained, and a variety of process gas control can also be realized. The equipment is exquisite and beautiful in appearance, with good peripheral expandability, suitable for universities and research institutes for experiments.
Features
1. Application temperature of RT-1000℃;
2. Intelligent programmable temperature controller with precise control, which can edit, store and call multi-segment program;
3. furnace shell structure, double-layer shell air-cooled structure;
4. stainless steel double sealing flange seal;
5. adjustable flange support structure at both ends to extend the service life of the quartz tube;
6. LED high-strength, vandal-resistant, all stainless steel buttons, durable;
7. over-temperature protection function, when the temperature exceeds the allowable set value automatically power off;
8. safety protection when the furnace body leakage automatic power off;
9. K-type thermocouple, accurate temperature control
10. Heating element is ceramic fiber heating module, heating wire embedded structure
Additional Options
Vacuum system: (rotary vane mechanical pump, diffusion pump unit, molecular pump unit);
Atmosphere system: (float flow meter, mass flow meter);
Note: options need to be configured to expand the cabinet
Technical Parameters
Equipment Model (Serial No.) | Operating Temperature (℃) | Outer Diameter of Furnace Tube (φ mm) | Length of Furnace Tube (L mm) | Heating Length (mm) | Number of Temperature Zones (zones) | External Dimension mm (W×H×D) | Voltage (V) | Power (kW) |
FGL-25/11/1 | RT~1000 | 25 | 1000 | 320 | 1 | Desktop Touch Screen 635*560*380 | 220 | 1.2 |
FGL-50/11/1 | RT~1000 | 50 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | 3.0 |
FGL-60/11/1 | RT~1000 | 60 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/1 | RT~1000 | 80 | 1000 | 420 | 1 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-50/11/2 | RT~1000 | 50 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | 3.2 |
FGL-60/11/2 | RT~1000 | 60 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/2 | RT~1000 | 80 | 1000 | 200/200 | 2 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-50/11/3 | RT~1000 | 50 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 | 6.0 |
FGL-60/11/3 | RT~1000 | 60 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 | |
FGL-80/11/3 | RT~1000 | 80 | 1250mm | 200/200/200 | 3 | Desktop Touch Screen 635*560*380 | 220 |
Notes:
1. Other pipe diameters, the number of temperature zones and the length of the heating zone can be customized according to customer process requirements.
2. Excluding flange, furnace tube, flange bracket and other vacuum unit connection dimensions.